Utilize este identificador para referenciar este registo: http://hdl.handle.net/1822/33257

TítuloFinite element analysis of pectus carinatum surgical correction via a minimally invasive approach
Autor(es)Neves, S. C.
Pinho, A. C. Marques de
Fonseca, Jaime C.
Rodrigues, Nuno F.
Coelho, Tiago Henriques
Pinto, Jorge Correia
Vilaça, João L.
Palavras-chavePectus carinatum
Finite element analysis
Reversed Nuss procedure
Minimally invasive approach
Data2015
EditoraTaylor & Francis
RevistaComputer methods in biomechanics and biomedical engineering
Resumo(s)Pectus carinatum (PC) is a chest deformity caused by a disproportionate growth of the costal cartilages compared to the bony thoracic skeleton, pulling the sternum towards, which leads to its protrusion. There has been a growing interest on using the 'reversed Nuss' technique as a minimally invasive procedure for PC surgical correction. A corrective bar is introduced between the skin and the thoracic cage and positioned on top of the sternum highest protrusion area for continuous pressure. Then, it is fixed to the ribs and kept implanted for about 2-3 years. The purpose of this work was to (a) assess the stresses distribution on the thoracic cage that arise from the procedure, and (b) investigate the impact of different positioning of the corrective bar along the sternum. The higher stresses were generated on the 4th, 5th and 6th ribs backend, supporting the hypothesis of pectus deformities correction-induced scoliosis. The different bar positioning originated different stresses on the ribs' backend. The bar position that led to lower stresses generated on the ribs backend was the one that also led to the smallest sternum displacement. However, this may be preferred, as the risk of induced scoliosis is lowered.
Tipoarticle
URIhttp://hdl.handle.net/1822/33257
DOI10.1080/10255842.2013.843675
ISSN1025-5842
1476-8259
Versão da editorahttp://dx.doi.org/10.1080/10255842.2013.843675
Arbitragem científicayes
AcessoopenAccess
Aparece nas coleções:HASLab - Artigos em revistas internacionais
ICVS - Artigos em Revistas Internacionais com Referee

Ficheiros deste registo:
Ficheiro Descrição TamanhoFormato 
neves sc_comp met biomech biomed eng 2015.pdf989,22 kBAdobe PDFVer/Abrir

Partilhe no FacebookPartilhe no TwitterPartilhe no DeliciousPartilhe no LinkedInPartilhe no DiggAdicionar ao Google BookmarksPartilhe no MySpacePartilhe no Orkut
Exporte no formato BibTex mendeley Exporte no formato Endnote Adicione ao seu Currículo DeGóis