Utilize este identificador para referenciar este registo: https://hdl.handle.net/1822/33202

Registo completo
Campo DCValorIdioma
dc.contributor.authorDias, Luís G.por
dc.contributor.authorVeloso, Ana C. A.por
dc.contributor.authorMachado, Adélio A. S. C.por
dc.contributor.authorPeres, António M.por
dc.date.accessioned2015-01-26T14:21:15Z-
dc.date.available2015-01-26T14:21:15Z-
dc.date.issued2012-
dc.identifier.citationDias, L. G.; Veloso, Ana C. A.; Machado, A. A. S. C.; Peres, A. M., Performance study of a potentiometric sensor array for lactic proteins analysis. IMCS 2012 - The 14th International Meeting on Chemical Sensors. Nuremberg, Germany, 20-23 May, 1332-1335, 2012. ISBN: 978-3-9813484-1-5-
dc.identifier.isbn978-3-9813484-1-5-
dc.identifier.urihttps://hdl.handle.net/1822/33202-
dc.description.abstractLactic proteins are complex biomolecules, possessing different molecular weights (from 19 kDa up to 66 kDa), which can be used as biomarkers for detecting food adulterations. This study reports for the first time the evaluation of two potentiometric sensor arrays, one electronic tongue (ET) using only cross-sensitivity chemical sensors and a hybrid-ET containing ionic-selective and cross-sensitivity chemical sensors. Although both devices could detect and distinguish soluble and insoluble lactic proteins, namely bovine serum albumin and three main casein fractions(alpha-, beta- and kappa-), the inclusion of ionic-selective sensors increased the device performance (100% of correct leave-oneout cross-validation classification for hybrid-ET against 94% for the ET) and reduced the number of sensors needed (5 for the hybrid-ET instead of 9 sensors used by the ET device). Finally, the results showed that with the hybrid-ET a second-order polynomial equation could be derived relating the measured potential of the aqueous solution and the logarithmic of the total casein concentration, with satisfactory determination coefficients (R2>0.99).por
dc.language.isoengpor
dc.rightsopenAccesspor
dc.subjectPotentiometric sensor arraypor
dc.subjectCross-sensitivity chemical sensorspor
dc.subjectIonic-selective chemical sensorspor
dc.subjectLactic proteinspor
dc.titlePerformance study of a potentiometric sensor array for lactic proteins analysispor
dc.typeconferencePaper-
dc.peerreviewedyespor
dc.commentsCEB12654por
sdum.publicationstatuspublishedpor
oaire.citationConferenceDate20 - 23 Maio 2012por
sdum.event.typeconferencepor
oaire.citationStartPage1332por
oaire.citationEndPage1335por
oaire.citationConferencePlaceNuremberg, Germanypor
oaire.citationTitleIMCS 2012 - The 14th International Meeting on Chemical Sensorspor
dc.date.updated2014-12-01T11:07:50Z-
dc.identifier.doi10.5162/IMCS2012/P2.1.2por
sdum.conferencePublicationIMCS 2012 - The 14th International Meeting on Chemical Sensorspor
Aparece nas coleções:CEB - Artigos em Livros de Atas / Papers in Proceedings

Ficheiros deste registo:
Ficheiro Descrição TamanhoFormato 
document_12654_1.pdf717,46 kBAdobe PDFVer/Abrir

Partilhe no FacebookPartilhe no TwitterPartilhe no DeliciousPartilhe no LinkedInPartilhe no DiggAdicionar ao Google BookmarksPartilhe no MySpacePartilhe no Orkut
Exporte no formato BibTex mendeley Exporte no formato Endnote Adicione ao seu ORCID