Utilize este identificador para referenciar este registo: https://hdl.handle.net/1822/24543

Registo completo
Campo DCValorIdioma
dc.contributor.authorTeixeira, P. F.-
dc.contributor.authorHilliou, L.-
dc.contributor.authorCovas, J. A.-
dc.contributor.authorMaia, J. M.-
dc.date.accessioned2013-07-03T13:59:39Z-
dc.date.available2013-07-03T13:59:39Z-
dc.date.issued2013-
dc.identifier.issn0035-4511por
dc.identifier.urihttps://hdl.handle.net/1822/24543-
dc.description.abstractThe most promising method capable of providing accurate measurements of the first and second normal-stress differences in shear flows at shear rates typical of polymer processing is the so-called hole-pressure method, but its use has not been as widespread as would be expected, namely due to the experimental difficulties associated with performing such experiments accurately. In this work, we use a small-scale modular slit die to assess the practical utility of the method for in-line monitoring of polymer melt flow. We provide a quantitative analysis of intrinsic error sources and use state-of-the-art data acquisition tools to minimize errors associated with pressure transducers. Our results demonstrate that the method can be used to accurately measure the viscosity and first normal-stress difference in melts but probably not the second normal-stress difference because the intrinsic errors are too high, even when the influence of all the potential error sources is minimized or eliminated.por
dc.description.sponsorshipThe authors acknowledge the financial support of the Center for Layered Polymeric Systems (NSF grant 0423914) and of the Foundation for Science and Technology, Portugal, through grants SFRH/BD/25311/2005, POCI/ EME/62461/2004, and PPCDT/EME/62461/2004por
dc.language.isoengpor
dc.publisherSpringer por
dc.rightsrestrictedAccesspor
dc.subjectFirst normal-stress differencepor
dc.subjectSecond normal-stress differencepor
dc.subjectSlit rheometrypor
dc.subjectPolymer meltpor
dc.subjectPolymer meltspor
dc.titleAssessing the practical utility of the hole-pressure method for the in-line rheological characterization of polymer meltspor
dc.typearticle-
dc.peerreviewedyespor
dc.relation.publisherversionhttp://link.springer.com/content/pdf/10.1007%2Fs00397-013-0695-5.pdfpor
sdum.publicationstatuspublishedpor
oaire.citationStartPage661por
oaire.citationEndPage672por
oaire.citationIssue7por
oaire.citationTitleRheologica Actapor
oaire.citationVolume52por
dc.identifier.doi10.1007/s00397-013-0695-5por
dc.subject.wosScience & Technologypor
sdum.journalRheologica Actapor
Aparece nas coleções:IPC - Artigos em revistas científicas internacionais com arbitragem

Ficheiros deste registo:
Ficheiro Descrição TamanhoFormato 
rheologica acta 2013 pressure hole.pdf
Acesso restrito!
author copy820,49 kBAdobe PDFVer/Abrir

Partilhe no FacebookPartilhe no TwitterPartilhe no DeliciousPartilhe no LinkedInPartilhe no DiggAdicionar ao Google BookmarksPartilhe no MySpacePartilhe no Orkut
Exporte no formato BibTex mendeley Exporte no formato Endnote Adicione ao seu ORCID