Utilize este identificador para referenciar este registo: https://hdl.handle.net/1822/23132

Registo completo
Campo DCValorIdioma
dc.contributor.authorReitmaier, S.-
dc.contributor.authorWolfram, U.-
dc.contributor.authorIgnatius, A.-
dc.contributor.authorWilke, H. - J.-
dc.contributor.authorGloria, A.-
dc.contributor.authorMartín-Martínez, José M.-
dc.contributor.authorSilva-Correia, Joana-
dc.contributor.authorOliveira, Joaquim M.-
dc.contributor.authorReis, R. L.-
dc.contributor.authorSchmidt, H.-
dc.date.accessioned2013-02-20T11:29:01Z-
dc.date.available2013-02-20T11:29:01Z-
dc.date.issued2012-10-
dc.date.submitted2012-10-
dc.identifier.issn1751-6161-
dc.identifier.urihttps://hdl.handle.net/1822/23132-
dc.description.abstractHydrogels are considered promising for disc regeneration strategies. However, it is currently unknown whether the destruction of the natural interface between nucleus and surrounding structures caused by nucleotomy and an inadequate annulus closure diminishes the mechanical competence of the disc. This in vitro study aimed to clarify these mechanisms and to evaluate whether hydrogels are able to restore the biomechanical behaviour of the disc. Nucleus pressure in an ovine intervertebral disc was measured in vivo during day and night and adapted to an in vitro axial compressive diurnal (15min) and night (30min) load. Effects of different defects on disc height and nucleus pressure were subsequently measured in vitro using 30 ovine motion segments. Following cases were considered: intact; annulus incision repaired by suture and glue; annulus incision with removal and re-implantation of nucleus tissue; and two different hydrogels repaired by suture and glue. The intradiscal pressure in vivo was 0.75 MPa during day and 0.5 MPa during night corresponding to an in vitro axial compressive force of 130 and 58 N, respectively. The compression test showed that neither the implantation of hydrogels nor the re-implantation of the natural nucleus, assumed as being the ideal implant, was able to restore the mechanical functionality of an intact disc. Results indicate the importance of the natural anchorage of the nucleus with its surrounding structures and the relevance of an appropriate annulus closure. Therefore, hydrogels that are able to mimic the mechanical behaviour of the native nucleus may fail in restoring the mechanical behaviour of the disc.por
dc.description.sponsorshipThis work was funded by the EU project DISC REGENERATION (NMP3-LA-2008-213904), and by the German Research Foundation (WI 1352 14-1).por
dc.language.isoengpor
dc.publisherElsevier Science BVpor
dc.rightsopenAccesspor
dc.subjectCompression testpor
dc.subjectDisc regenerationpor
dc.subjectHydrogelspor
dc.subjectIn vitropor
dc.subjectIn vivopor
dc.subjectintervertebral discpor
dc.subjectNucleus replacementpor
dc.titleHydrogels for nucleus replacement: facing a biomechanical challengepor
dc.typearticle-
dc.peerreviewedyespor
dc.commentshttp://www.3bs.uminho.pt/node/15833por
sdum.publicationstatuspublishedpor
oaire.citationStartPage67por
oaire.citationEndPage77por
oaire.citationIssue2012por
oaire.citationVolume14por
dc.date.updated2013-02-19T16:37:49Z-
dc.identifier.doi10.1016/j.jmbbm.2012.05.010por
dc.identifier.pmid22963748por
dc.subject.wosScience & Technologypor
sdum.journalJournal of the Mechanical Behavior of Biomedical Materialspor
Aparece nas coleções:3B’s - Artigos em revistas/Papers in scientific journals

Ficheiros deste registo:
Ficheiro Descrição TamanhoFormato 
1349168797_Reitmaier et al 2012_JMechBehavBiomedMater.pdf1,55 MBAdobe PDFVer/Abrir

Partilhe no FacebookPartilhe no TwitterPartilhe no DeliciousPartilhe no LinkedInPartilhe no DiggAdicionar ao Google BookmarksPartilhe no MySpacePartilhe no Orkut
Exporte no formato BibTex mendeley Exporte no formato Endnote Adicione ao seu ORCID