Utilize este identificador para referenciar este registo: https://hdl.handle.net/1822/1745

Registo completo
Campo DCValorIdioma
dc.contributor.authorVieira, A. C.-
dc.contributor.authorRibeiro, A. R.-
dc.contributor.authorRocha, L. A.-
dc.contributor.authorCelis, J. P.-
dc.date.accessioned2005-05-23T16:24:44Z-
dc.date.available2005-05-23T16:24:44Z-
dc.date.issued2004-09-
dc.identifier.citationEUROPEAN CORROSION CONFERENCE, Nice, 2004 - "EUROCORR 2004 : Long term Prediction & Modelling of Corrosion". [S.l. : s.n., 2004]. p. 1-9.eng
dc.identifier.urihttps://hdl.handle.net/1822/1745-
dc.description.abstractDental implants are used to replace teeth lost due to decay, trauma or periodontal disease. In last years, the demand for such implants has increased exponentially due mostly to the ageing of the population and/or increased reliability of implant therapy. To choose a material for a particular rehabilitation treatment different characteristics must be considered such as mechanical strength, elastic properties, machinability, chemical resistance, etc. There is, however, one aspect that is always of prime importance; namely how the tissue at the implant site responds to the chemical disturbance imposed by the presence of a foreign material. In this work, commercially pure titanium (grade 2) was selected mainly due to its excellent corrosion behaviour and biocompatibility, that make this material one of the most used in dentistry. The tribocorrosion behaviour of the material in conditions simulating mastication, when in contact with artificial saliva solutions was investigated. Corundum was used as counterface material. The tests were performed, at MTM- KULeuven (Belgium), in a fretting machine specially adapted for tribocorrosion experiments. A normal load of 2 N was applied to the specimens and a displacement amplitude of 200µm at a frequency of 1 Hz. The number of cycles was varied between 5.000 and 10.000. In order to simulate different environmental conditions, simple artificial saliva (0.7%KCl + 1,2%NaCl; pH =6), artificial saliva with corrosion catalyst (citric acid), and artificial saliva with anodic, cathodic and organic corrosion inhibitors (sodium nitrite, calcium carbonate or benzotriazole, respectively), was used. The tribocorrosion degradation mechanisms were investigated by Electrochemical Noise technique (TEN), which combines Electrochemical Emission Spectroscopy with fretting tests [1]. After being tested, the surface of the samples was investigated by SEM and EDX. Roughness measurements and wear volume measurements were also performed. The depassivation/repassivation phenomena occurring during the tests were clearly detected, and are discussed. Considering the influence of the corrosion inhibitors, it was possible to observe that the degree of protection varies with the nature of the inhibitor.eng
dc.description.sponsorship(undefined)por
dc.language.isoengeng
dc.rightsopenAccesseng
dc.subjectTribocorrosion,eng
dc.subjectDental implantseng
dc.subjectDifferent types of salivapor
dc.subjectTitanium grade 2por
dc.titleTribocorrosion behaviour of titanium in artificial saliva solutionseng
dc.typeconferencePapereng
dc.peerreviewedyeseng
sdum.conferencePublicationEUROCORR 2004 - European Corrosion Conference: Long Term Prediction and Modelling of Corrosionpor
Aparece nas coleções:CIICS - Artigos em revistas de circulação internacional com arbitragem científica
DEM - Publicações em actas de encontros científicos / Papers in conference proceedings

Ficheiros deste registo:
Ficheiro Descrição TamanhoFormato 
300-vieira.pdf286 kBAdobe PDFVer/Abrir

Partilhe no FacebookPartilhe no TwitterPartilhe no DeliciousPartilhe no LinkedInPartilhe no DiggAdicionar ao Google BookmarksPartilhe no MySpacePartilhe no Orkut
Exporte no formato BibTex mendeley Exporte no formato Endnote Adicione ao seu ORCID