Utilize este identificador para referenciar este registo:
https://hdl.handle.net/1822/16143
Registo completo
Campo DC | Valor | Idioma |
---|---|---|
dc.contributor.author | Fernández-López, Helena | - |
dc.contributor.author | Macedo, Pedro | - |
dc.contributor.author | Afonso, José A. | - |
dc.contributor.author | Correia, J. H. | - |
dc.contributor.author | Simões, Ricardo | - |
dc.date.accessioned | 2012-01-03T16:17:16Z | - |
dc.date.available | 2012-01-03T16:17:16Z | - |
dc.date.issued | 2009-04 | - |
dc.identifier.isbn | 978-963-9799-42-4 | - |
dc.identifier.uri | https://hdl.handle.net/1822/16143 | - |
dc.description.abstract | Low power consumption and small footprint make 802.15.4/ZigBee based devices well suited for personal healthcare applications, representing a promising alternative to patient monitoring under important scenarios such as emergency, postop, continuous care, and chronic diseases. However, their use in a healthcare facility to monitor several mobile patients poses several difficulties, mainly because this protocol was primarily designed to operate in low data rate scenarios. This paper presents simulation results used to evaluate important quality of service (QoS) markers and, ultimately, estimate the maximum number of sensors that could integrate a wireless vital signs monitoring system. Results show that the system is able to carry the signals from 30 ECG sensors with delivery ratio higher than 99% in the considered scenario, provided that an adequate number of retransmissions are allowed. | por |
dc.description.sponsorship | Fundação para a Ciência e a Tecnologia (FCT) | por |
dc.description.sponsorship | Grupo AMI – Assistência Médica Integral (Casa de Saúde Guimarães, SA) | por |
dc.language.iso | eng | por |
dc.publisher | IEEE | por |
dc.rights | openAccess | por |
dc.subject | Vital signs monitoring | por |
dc.subject | Performance evaluation | por |
dc.subject | Quality of service | por |
dc.subject | ZigBee | por |
dc.subject | Wireless sensor networks | por |
dc.subject | Vital signals monitoring | por |
dc.title | Performance evaluation of a ZigBee-based medical sensor network | por |
dc.type | conferencePaper | por |
dc.peerreviewed | yes | por |
sdum.publicationstatus | published | por |
oaire.citationConferencePlace | London, UK | por |
oaire.citationTitle | 3rd International Conference on Pervasive Computing Technologies for Healthcare, 2009 (PervasiveHealth 2009) | por |
dc.identifier.doi | 10.4108/ICST.PERVASIVEHEALTH2009.6002 | por |
sdum.conferencePublication | 3rd International Conference on Pervasive Computing Technologies for Healthcare, 2009 (PervasiveHealth 2009) | por |
Aparece nas coleções: | DEI - Artigos em atas de congressos internacionais |
Ficheiros deste registo:
Ficheiro | Descrição | Tamanho | Formato | |
---|---|---|---|---|
WiPH2009-s.pdf | 499,42 kB | Adobe PDF | Ver/Abrir |