Utilize este identificador para referenciar este registo: https://hdl.handle.net/1822/14549

Registo completo
Campo DCValorIdioma
dc.contributor.authorSilva, A. F.-
dc.contributor.authorCarmo, João Paulo Pereira-
dc.contributor.authorMendes, P. M.-
dc.contributor.authorCorreia, J. H.-
dc.date.accessioned2011-11-22T15:21:18Z-
dc.date.available2011-11-22T15:21:18Z-
dc.date.issued2011-06-02-
dc.date.submitted2010-11-23-
dc.identifier.issn0957-0233por
dc.identifier.urihttps://hdl.handle.net/1822/14549-
dc.description.abstractA respiratory and cardiac-frequency sensor has been designed and manufactured to monitor both components with a single fiber Bragg grating (FBG) sensor. The main innovation of the explored system is the structure in which the FBG sensor is embedded. A specially developed polymeric foil allowed the simultaneous detection of heart rate and respiration cycles. The PVC has been designed to enhance the sensor sensitivity. In order to retrieve both components individually, a signal processing system was implemented for filtering out the respiratory and cardiac frequencies. The developed solution was tested along with a commercial device for referencing, from which the proposed system reliability is concluded. This optical-fiber system type has found an application niche in magnetic resonance imaging (MRI) exam rooms, where no other types of sensors than optical ones are advised to enter due to the electromagnetic interference.por
dc.description.sponsorshipFundação para a Ciência e a Tecnologia (FCT)por
dc.language.isoengpor
dc.publisherIOP Publishingpor
dc.rightsrestrictedAccesspor
dc.subjectFiber-optic instrumentspor
dc.subjectFiber Bragg gratingspor
dc.subjectHealthcare monitoringpor
dc.subjectIntegrationpor
dc.subjectoptical fiber sensorpor
dc.subjectfiber Bragg gratingpor
dc.titleSimultaneous cardiac and respiratory frequency measurement based on a single fiber Bragg grating sensorpor
dc.typearticlepor
dc.peerreviewedyespor
dc.relation.publisherversionhttp://dx.doi.org/10.1088/0957-0233/22/7/075801por
sdum.publicationstatuspublishedpor
oaire.citationStartPage1por
oaire.citationEndPage5por
oaire.citationIssue7por
oaire.citationTitleMeasurement Science and Technologypor
oaire.citationVolume22por
dc.identifier.doi10.1088/0957-0233/22/7/075801por
dc.subject.wosScience & Technologypor
sdum.journalMeasurement Science and Technologypor
Aparece nas coleções:CAlg - Artigos em revistas internacionais / Papers in international journals
DEI - Artigos em revistas internacionais

Ficheiros deste registo:
Ficheiro Descrição TamanhoFormato 
Simultaneous cardiac and respiratory frequency measurement based on a single fiber Bragg grating sensor.pdf
Acesso restrito!
1,32 MBAdobe PDFVer/Abrir

Partilhe no FacebookPartilhe no TwitterPartilhe no DeliciousPartilhe no LinkedInPartilhe no DiggAdicionar ao Google BookmarksPartilhe no MySpacePartilhe no Orkut
Exporte no formato BibTex mendeley Exporte no formato Endnote Adicione ao seu ORCID